GA
Medical & LabOpen now6d 12h left

Follet Refridgerator

DECATUR, GeorgiaListed by GSA AuctionsDepartment of Medicine and Surgery

Listing description

What the seller provided

Overview Follett REF25i-4S-R0000G biological refrigerator with 24.6 cubic foot nominal capacity and serial number S49416-343-25. This lot is in unused condition. Specifications • Make: Follett • Model: REF25i-4S-R0000G • Serial Number: S49416-343-25 Key Features • Variable-speed compressor with ±1°C temperature uniformity. • Nominal capacity of 24.6 cubic feet with vaccine storage capacity of 16.8 cubic feet. • 7-inch LCD touchscreen for temperature control with USB data logging capability. • NSF/ANSI 456-certified for vaccine storage applications. • Energy Star certified using R600a refrigerant. • Operating range of 2.2-10°C with factory preset at 4.4°C. • Audible and visual alarms for high/low temperature, door open, power failure, low battery, and probe failure. • Anti-freeze compressor shutoff prevents over-cooling. • Stainless steel interior and exterior construction. • Dual-pane glass door with low-E coating and ADA-compliant handle. • Four adjustable epoxy-coated shelves supporting up to 125 pounds each. • Quick-connect RTD probe with 1-year NIST-traceable certification. • LED interior lighting with full-length illumination. • Self-closing hinges with 90-degree hold feature. • Heavy-duty dual casters with locks. • 115V/60Hz power requirement with NEMA 5-15 hospital-grade plug. Condition & Markings • Parts may be missing, and repairs may be required. Inspection and Removal • Inspection and Removal: Available Monday through Friday, by confirmed appointment only. The site is closed on federal holidays. Contact the property custodian (listed below) to schedule an appointment. • Property Inspection: Bidders are strongly encouraged to inspect the property prior to placing a bid to evaluate its condition and suitability. By bidding without an inspection, bidders assume the risk of potential omissions in the description. • Removal Responsibilities: The successful bidder is solely responsible for all aspects of removal, including packing, crating, banding, loading, and shipping. The agency will not provide assistance. • Authorized Third-Party Removal: The authorized third-party agent must present a Letter of Authorization from the high bidder (see terms and conditions for details), a copy of the purchasers receipt, and a valid photo ID at the time of removal. HAZARDOUS MATERIALS STATEMENT: Purchaser must complete and sign the Hazardous Materials Form located in the Documents section of this offering and submit it to the Sales Contracting Officer. The purchaser is responsible for complying with all applicable federal, state, and local environmental, safety, transportation, and disposal laws and regulations. Award of property will not be made until the required form has been received. Disclaimer • The condition of the property is not warranted. Pictures are not warranted.

Record details

Agency
Department of Medicine and Surgery
Bureau
Department of Medicine and Surgery
Bid increment
$25
Reserve
Yes
Sale location
GSA, FAS Northeast Capital Zone (QSDCCB)
Contact
candice.threatt@gsa.gov
Phone
3128868677

Keep exploring

Related medical & lab auctions in Georgia

Browse all medical & lab
GV

Medical & Lab

GSA Auctions

Open

Omnicell OmniSupplier OS224 Medical Supply Cabinets

DECATUR, Georgia

Overview This lot contains two Omnicell OmniSupplier OS224 medical supply cabinets designed for secure storage and controlled dispensing of medical supplies in clinical environments. The cabinets are in used condition and are being sold as a pair. Specifications Manufacturer: Omnicell Model: OS224 Product Line: OmniSupplier Quantity: 2 Unit of Issue: Pair Electrical Rating: 115/230 VAC, 2 AMP,

more...

Current bid

$25

Time left

4d 12h

GV

Medical & Lab

GSA Auctions

Open

CHAIR-TRANSFER PATIENT

AUGUSTA, Georgia

Overview Transmotion LLC TMM6 Patient transfer chair. This lot is in used condition. Chair functionality has not been tested or verified. Key Features • Designed for patient transfer applications. Condition & Markings • This lot is in used condition. Parts may be missing, and repairs may be required. • This item contains hazardous material. • The bidder will comply with all applicable Federal,

more...

Auction terms

See source

Time left

4d 12h

GV

Medical & Lab

GSA Auctions

Open

Hill-Rom P8000 Stretcher

AUGUSTA, Georgia

Overview Hill-Rom P8000 transport stretcher manufactured in 2001. This medical stretcher is in usable condition with normal wear consistent with age. Key Features • Full frame construction with integrated side rails. • Mobility wheel system for transport capability. • Includes mattress. Condition & Markings • This lot is in used condition. Parts may be missing, and repairs may be required. •

more...

Auction terms

See source

Time left

4d 12h